e
STATION
-
Warning and error messages
The output is connected to a battery with incorrect polarity.
This will be displayed in case of detecting an interruption of the
connection between battery and output or voluntarily disconnecting the
charge lead during the operation of charge or discharge on output.
The voltage of one of the cell in the Lithium battery pack is too low. Please
check the voltage of cells one by one.
The cell-count of Lithium battery pack was selected incorrectly. Verify the
cell-count carefully.
The charger detects the voltage is lower than you set at Lithium program.
Please check the cell-count of the battery pack.
BC8DX incorporates a various functions of protective and monitoring the system to verify functions and
the state of its electronics. In any case of occurring error, the screen displays the cause of error that is
self-explanatory with audible sound.
The charger detects the voltage is higher than you set at Lithium program.
Please check the cell-count of the battery pack.
There are bad connection at the individual connector. Please check the
connector and cables carefully.
There is a short-circuit at output. Please check the charging leads or
output cable of battery pack.
The voltage of input power drops below the limit.
There happens the malfunction at the charger circuit by any reason. The
charger should be repaired at the factory.
The voltage of one of the cell in the Lithium battery pack is too high.
Please check the voltage of cells one by one.
The internal temperature of the unit goes too high. Cool down the unit.
!
Check connection ...
Reversed polarity
STOP/ESC
Check charger ...
Over-temperature
STOP/ESC
Check connection ...
Connection break
STOP/ESC
Check cell-count ...
Incorrect cell-count
STOP/ESC
Check charger ...
Break-down
STOP/ESC
Check connection ...
Short-circuit
STOP/ESC
Check battery ...
Low voltage
STOP/ESC
Check balancer ...
Comm. error
STOP/ESC
Balance error ...
Low cell vol.
STOP/ESC
Check battery ...
High voltage
STOP/ESC
Balance error ...
High cell vol.
STOP/ESC
Balance error ...
Bad connection
STOP/ESC
Balance error ...
Ref. data fail
STOP/ESC
Check power ...
Low input volt
!
- 21 -
STOP/ESC
!
!
!
The balancing circuit had been damaged. The balance function can not be
used, and the charger needs to be repaired at our factory.
The charger can not read out the individual voltages correctly because of
malfunction of main processor. The charger needs to be repaired.